hi Andreas
i have explained how an ISO9141-2 will be initialized in a recent message in
opendiag archive. i uploaded a file ISO9141 in file section of opendiag for
introduction and signal level.
after an succefully init you send ( 10400 baud ) to ECU
0x68 0x6A 0xF1 0x03 CS to read the DTC
response 0x48 0x6B ECUAdd 0x43 DTC1highbyte
DTC1lowbyte .................. CS
0x68 0x6A 0xF1 0x04 CS to clear DTCs
response 0x48 0x6B ECUadd 0x44 CS
regards
Bülent
----- Original Message -----
From: "Andreas Siemering" <student@...>
To: <opendiag@yahoogroups.com>
Sent: Saturday, July 12, 2003 8:13 PM
Subject: RE: [opendiag] Keyword 0808
> Hi Bülent,
>
> thanks for your help. Is there any documentation about
> ISO9141-2 communication available on the web? Because
> I have no idea how to establish communication since
> none of the programms worked. Maybe with some papers
> I can start develop my own application. At the moment
> I am only interested in reading and deleting fault codes.
>
> Regards
> Andreas
>
>
>