Hi
service 9 is same as service 1.
request first the supported info_types with
$68,$6a,$F1,$09,$00,CS
even if the info_type is supported ( corresponding bit position is 1 ) you get a response. if it is 0. also no info available in ECU.
it needs keep alive every 4 sec. and no response time out is 60 sec. after our tests the response can come in l 6 sec.
the valid info_types are 2 ... 6
regards
Bülent
----- Original Message -----
From: Kenny
To: opendiag@yahoogroups.com
Sent: Tuesday, October 14, 2003 3:43 PM
Subject: [opendiag] Can't read VIN
Please forgive me if this is a re-post - browser crashed posting
last message.
I have built a stand-alone scanner, which works great. I can read
values, read DTCs, clear DTCs etc but one request won't work...
When I send a mode $09 PID $02 (Read VIN) I get no reply at all.
The values I'm sending (after connecting to 0x33) are :-
$68,$6a,$F1,$09,$02,$ce
But I get no reply.
However if I send
$68,$6a,$F1,$01,$0d,$d1 - get vehcile speed, this works fine.
Any ideas anyone?
Yahoo! Groups Sponsor
ADVERTISEMENT
To unsubscribe from this group, send an email to:
opendiag-unsubscribe@egroups.com
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
[Non-text portions of this message have been removed]
Received on Tue Oct 14 06:33:30 2003
This archive was generated by hypermail 2.1.8 : Wed Jan 02 2008 - 00:56:01 CET