Re: ISO fast init

From: pawel_pazderski <olsen@...>
Date: Wed May 30 2007 - 13:25:01 CEST

Hello,

You said you got response asking 68 6A F1... after succeeded slow
init.
Check what kind of key words you get. I think you got 08h 08h or 94h
94h which are charakteristic to ISO 9141-2 slow init and that is why
the module responds to your 68 6A F1... However it is not KWP2000
slow protocol and you cannot use the same sending routine to 9141-2
and KWP2000.

You can`t ask 68 6A F1... in none of KWP2000 types. (neither slow nor
fast)

--- In opendiag@yahoogroups.com, "smit3207651" <smit320@...> wrote:
>
> Thanks for reply,
>
>
> I have made a program that makes a wakeup slow init.
> And a routine that asks all the pids.(example 68 6A F1.....)
> This works.
>
> I have also made program that wakes up fast init.
> And now it asks 1 pid (for trying) (C2 33 F1......)
> This works also.
> (i tryed it on a fastinit car)
>
> But if i can (use)ask 68 6A F1.... with fastinit then i can use
> same routine i made for slow init program.
> But i don't have a(fastinit)car here right now to try it.
>
> Can i ask 68 6A F1....... on a fast initcar?
> Or must i always ask C2 33 F1... when car is KW2000
> Mario
>

 
Received on Wed May 30 04:29:07 2007